Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 238
Filtrar
1.
Clin Res Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38436739

RESUMEN

BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.

2.
Clin Res Cardiol ; 2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37606854

RESUMEN

AIMS: The MicraVR™ transcatheter pacing system (TPS) has been implemented into clinical routine for several years. The primary recipients are patients in need for VVI pacing due to bradycardia in the setting of atrial fibrillation (AF). Implantation safety and acute success have been proven in controlled studies and registries. So far only few long-term real-life data on TPS exist. We report indication, procedure and outcome data from two high-volume implanting German centers. METHODS: Between 2016 and 2019, 188 (of 303) patients were included. During follow-up (FU), TPS interrogation was performed after 4 weeks and thereafter every 6 months. RESULTS: Indication for TPS implantation in 159/188 (85%) patients was permanent or intermittent AV block III° in the setting of atrial fibrillation. The mean procedure duration was 50 min [35.0-70.0]. The average acute values after system release were: thresholds: 0.5V [0.38-0.74]/0.24ms; R-wave sensing: 10.0mV [8.1-13.5]; impedance: 650 Ohm [550-783]; RV-pacing demand: 16.9% [0.9-75.9]; and battery status: 3.15 V [3.12-3.16]. During FU of 723.4 ± 597.9 days, neither pacemaker failure nor infections were reported. Long-term FU revealed: thresholds: 0.5V [0.38-0.63]/0.24 ms; sensing: 12.3mV [8.9-17.2]; impedance: 570 Ohm [488-633]; RV-pacing demand: 87.1% [29.5-98.6]; and battery status 3.02 V [3.0-3.1]. Forty-three patients died from not-device-related causes. CONCLUSION: This to date largest German long-term dataset for MicraVR™ TPS implantation revealed stable device parameter. Foremost, battery longevity seems to fulfill predicted values despite a significant increase in RV-pacing demand over time and even in patients with consecutive AV-node ablation. Of note, no infections or system failure were observed.

4.
Heart ; 109(22): 1706-1713, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37407220

RESUMEN

OBJECTIVE: After transcatheter aortic valve implantation (TAVI), the optimal regimen of anticoagulant therapy in patients with an additional indication for oral anticoagulation remains a matter of debate. This study investigates the efficacy of direct oral anticoagulants (DOACs) versus vitamin K antagonists (VKAs) in patients after TAVI in a real-world population. METHODS: The German Aortic Valve RegistrY (GARY) is a prospective, multicentre registry enrolling patients undergoing invasive treatment for aortic valve disease. From January 2011 to December 2019, 1 41 790 patients from 92 hospitals in Germany were enrolled. Anticoagulatory treatment regimens were assessed at hospital discharge for patients after TAVI procedures. All-cause mortality and the combined endpoint 'cardiac and cerebrovascular events' containing myocardial infarction, stroke, transient ischaemic attack, aortic prosthesis reintervention and all-cause mortality in the first year after TAVI were examined by treatment regimen. RESULTS: Of 45 598 patients (mean age 80.7±5.7 years, 49.3% males) undergoing TAVI, 16 974 patients (37.2%) received an anticoagulant regimen that included VKA or DOAC. Hereof, the majority of patients were prescribed VKA (n=11 333, 66.8%) compared with DOAC (n=5641, 33.2%) with an increase of DOAC use from 9.4% in 2011 to 69.9% in 2019. During the 1-year follow-up, the absolute event rates per 100 person-years for all-cause mortality and the combined endpoint cardiac and cerebrovascular events were 1.9 and 1.3 for VKA-treated and 1.7 and 1.2 for DOAC-treated patients, respectively. After adjustment for baseline confounders, all-cause mortality (HR 0.95, 95% CI 0.88 to 1.01, p=0.114) and cardiac and cerebrovascular event-free survival (HR 0.93, 95% CI 0.86 to 1.01, p=0.071) did not differ significantly between VKA and DOAC groups. CONCLUSIONS: This study supports evidence of the efficacy of DOAC use after TAVI in patients with an indication for oral anticoagulation.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Anticoagulantes/efectos adversos , Válvula Aórtica/cirugía , Fibrinolíticos , Vitamina K , Resultado del Tratamiento , Factores de Riesgo
5.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
Eur Heart J Digit Health ; 4(3): 207-215, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37265862

RESUMEN

Aims: Coronary artery disease (CAD) remains the leading cause of death worldwide. 'Stable' CAD is a chronic progressive condition, which recent European guidelines recommend referring to as 'chronic coronary syndrome' (CCS). Despite therapeutic advances, morbidity and mortality among patients with CCS remain high. Optimal secondary prevention in patients with CCS includes optimization of modifiable risk factors with behavioural changes and pharmacological therapy. The CHANGE study aims to provide evidence for optimization of secondary prevention in CCS patients by using a smartphone application (app). Methods and results: The CHANGE study is designed as a prospective, randomized, controlled trial with a 1:1 allocation ratio, which is currently performed in nine centres in Germany in a parallel group design. 210 patients with CCS will be randomly allocated either to the control group (standard-of-care) or to the intervention group, who will be provided the VantisTherapy* app in addition to standard-of-care to incorporate secondary prevention into their daily life. The study will be performed in an open design. Outcomes will be assessed using objective data from three in-person visits (0, 12, and 24 weeks). Primary outcomes will involve adherence to secondary prevention recommendations and quality of life (QoL). The recruitment process started in July 2022. Conclusion: The CHANGE study will investigate whether a smartphone-guided secondary prevention app, combined with a monitor function compared with standard-of-care, has beneficial effects on overall adherence to secondary prevention guidelines and QoL in patients with CCS. Trial registration: The study is listed at the German study registry (DRKS) under the registered number DRKS00028081.

7.
EuroIntervention ; 19(1): 18-19, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-37170564
8.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858660

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Mortalidad Hospitalaria , Resultado del Tratamiento , Corazón
9.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36649387

RESUMEN

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Tiempo , Resultado del Tratamiento , Sistema de Registros , Diseño de Prótesis , Factores de Riesgo
11.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36331961

RESUMEN

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Incidencia , Factores de Riesgo , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Ecocardiografía
12.
Heart Vessels ; 38(2): 274-283, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36251050

RESUMEN

In this prospective observational study, we investigated the impact of geriatric syndromes and frailty on mortality and evaluated the prognostic value of different frailty, nutritional, and geriatric assessment tools in high-risk patients with severe mitral valve regurgitation (MR) who were evaluated for mitral valve therapies including surgical, interventional, and conservative treatment options. We prospectively assessed multiple parameters including the CONUT Score, the Katz Index of independence in activities of daily living (ADL), the Fried Frailty Phenotype (FFP), and the Essential Frailty Toolset (EFT) Score in 127 patients with severe symptomatic MR requiring surgical/interventional treatment versus conservative monitoring. We compared their predictive value on mortality including multivariate regression analysis to identify the most suitable tool to predict outcomes in these patient groups. The frailty syndrome as assessed with the CONUT Score, Katz Index, EFT Score, and FFP was associated with higher rates of comorbidities, significantly higher risk scores such as logistic EuroSCORE, EuroSCORE II, and STS-PROM, and significantly higher mortality rates. The EFT Score and FFP were independent predictors of one-year all-cause mortality in our study cohort (EFT Score: HR 1.9, 95% CI 1.2 to 3.2; p = 0.01; FFP: HR 1.8, 95% CI 1.1 to 3.1; p = 0.015). Geriatric syndromes and frailty are associated with increased mortality in high-risk patients with symptomatic severe MR. The EFT Score and the FFP were independent predictors of one-year all-cause mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Fragilidad/complicaciones , Fragilidad/diagnóstico , Anciano Frágil , Actividades Cotidianas , Insuficiencia de la Válvula Mitral/cirugía , Síndrome , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Evaluación Geriátrica
13.
Clin Cardiol ; 46(1): 67-75, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36259730

RESUMEN

BACKGROUND: Despite major advances, transcatheter aortic valve replacement (TAVR) is still associated with procedure-specific complications. Although previous studies reported lower bleeding rates in patients receiving protamine for heparin reversal, the optimal protamine-to-heparin dosing ratio is unknown. HYPOTHESIS: The aim of this study was a comparison of two different heparin antagonization regimens for the prevention of bleeding complications after TAVR. METHODS: The study included 1446 patients undergoing TAVR, of whom 623 received partial and 823 full heparin antagonization. The primary endpoint was a composite of 30-day mortality, life-threatening, and major bleeding. Safety endpoints included stroke and myocardial infarction at 30 days. RESULTS: Full antagonization of heparin resulted in lower rates of the primary endpoint as compared to partial heparin reversal (5.6% vs. 10.4%, p < .01), which was mainly driven by lower rates of life-threatening (0.5% vs. 1.6%, p = .05) and major bleeding (3.2% vs. 7.5%, p < .01). Moreover, the incidence of major vascular complications was significantly lower in patients with full heparin reversal (3.5% vs. 7.5%, p < .01). The need for red-blood-cell transfusion was lower in patients receiving full as compared to partial heparin antagonization (10.4% vs. 15.9%, p < .01). No differences were observed in the incidence of stroke and myocardial infarction between patients with full and partial heparin reversal (2.2% vs. 2.6%, p = .73 and 0.2% vs. 0.4%, p = .64, respectively). CONCLUSIONS: Full heparin antagonization resulted in significantly lower rates of life-threatening and major bleeding after TAVR as compared to partial heparin reversal. The occurrence of stroke and myocardial infarction was low and comparable between both groups.


Asunto(s)
Estenosis de la Válvula Aórtica , Infarto del Miocardio , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Heparina/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Protaminas/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/inducido químicamente , Infarto del Miocardio/prevención & control , Infarto del Miocardio/complicaciones , Válvula Aórtica/cirugía
14.
Cardiovasc Res ; 119(3): 857-866, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35727948

RESUMEN

AIMS: The present study aims to characterize the genetic risk architecture of bicuspid aortic valve (BAV) disease, the most common congenital heart defect. METHODS AND RESULTS: We carried out a genome-wide association study (GWAS) including 2236 BAV patients and 11 604 controls. This led to the identification of a new risk locus for BAV on chromosome 3q29. The single nucleotide polymorphism rs2550262 was genome-wide significant BAV associated (P = 3.49 × 10-08) and was replicated in an independent case-control sample. The risk locus encodes a deleterious missense variant in MUC4 (p.Ala4821Ser), a gene that is involved in epithelial-to-mesenchymal transformation. Mechanistical studies in zebrafish revealed that loss of Muc4 led to a delay in cardiac valvular development suggesting that loss of MUC4 may also play a role in aortic valve malformation. The GWAS also confirmed previously reported BAV risk loci at PALMD (P = 3.97 × 10-16), GATA4 (P = 1.61 × 10-09), and TEX41 (P = 7.68 × 10-04). In addition, the genetic BAV architecture was examined beyond the single-marker level revealing that a substantial fraction of BAV heritability is polygenic and ∼20% of the observed heritability can be explained by our GWAS data. Furthermore, we used the largest human single-cell atlas for foetal gene expression and show that the transcriptome profile in endothelial cells is a major source contributing to BAV pathology. CONCLUSION: Our study provides a deeper understanding of the genetic risk architecture of BAV formation on the single marker and polygenic level.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Animales , Humanos , Enfermedad de la Válvula Aórtica Bicúspide/metabolismo , Enfermedad de la Válvula Aórtica Bicúspide/patología , Válvula Aórtica/patología , Enfermedades de las Válvulas Cardíacas/patología , Estudio de Asociación del Genoma Completo , Pez Cebra/genética , Células Endoteliales/metabolismo
15.
Eur Heart J Suppl ; 24(Suppl J): J25-J29, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518888

RESUMEN

Complete revascularization (CR) in patients with multi-vessel disease improves outcomes. The use of percutaneous left-ventricular assist devices, such as the Impella heart pump, is useful to minimize the risk of haemodynamic compromise in complex higher risk and clinically indicated patients. The recently published data from the PROTECT III trial suggest more CR during Impella-protected percutaneous coronary intervention with more extensive lesion preparation and treatment, resulting in the reduced need for repeat revascularization. To achieve CR and improve survival, procedural guidance by intravascular imaging, extensive lesion preparation, debulking with atherectomy devices, advanced chronic total occlusion revascularization techniques, and post-interventional treatment with modern anti-platelet medication are essential.

17.
Eur Heart J Suppl ; 24(Suppl J): J37-J42, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518892

RESUMEN

Despite the routine use of percutaneous mechanical circulatory support (pMCS) with the Impella heart pump, vascular and bleeding complications may occur during removal with or without pre-closure. To safely close the large-bore access (LBA), post-hoc selection of the appropriate treatment of vascular complications is critical to patient recovery and survival. Femoral artery access is typically utilized for LBA, and percutaneous axillary artery access is a common alternative, especially in the instance of severe peripheral artery disease. Optimization of patient outcomes and efficiency of pMCS can be achieved with adequate arterial access using state-of-the-art techniques. Impella removal techniques with or without pre-closure will be addressed as well as the management of large-bore femoral access complications. In addition, treatment strategies to manage patient deterioration during a protected high-risk percutaneous coronary intervention will be provided.

18.
Eur Heart J Open ; 2(4): oeac045, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35983406

RESUMEN

Aims: Inflammatory activation of leukocytes may limit prognosis of patients (pts) with severe aortic valve stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Leukocyte telomere length (LTL) is a marker of proliferative capacity and inflammatory responsiveness but the impact of LTL on the prognosis in AS remains elusive. The aim of this study was to analyse the association of LTL with inflammatory markers and prognosis of pts undergoing TAVR. Methods and results: LTL was analysed using quantitative real-time PCR in 285 consecutive pts (median age 82 years) undergoing TAVR and correlated with 18-month all-cause mortality. C-reactive protein was significantly elevated in pts with the longest LTL (P = 0.017), paralleled by increased procalcitonin (PCT) serum levels (P = 0.0006). This inflammatory reaction was accompanied by increased myeloid cells in the highest LTL tertile, mainly a rise in circulating neutrophils (P = 0.0025) and monocytes (P = 0.01). Multivariate analysis revealed LTL (HR 2.6, 95%CI 1.4-5.1, P= 0.004) and PCT levels (HR 4.3, 95%CI 1.7-11.0, P = 0.003) as independent predictors of mortality. Conclusions: Longer LTL is associated with increased mortality after TAVR. This might be explained by enhanced proliferative capacity of cells resulting in myeloid and systemic inflammation. Our findings suggest that targeting the specific inflammation pathways could present a novel strategy to augment survival in selected patients with degenerative aortic stenosis.

19.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-35926921

RESUMEN

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 100(5): 850-859, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35989489

RESUMEN

BACKGROUND: A significant number of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) suffer from extra-aortic cardiac damage. Few studies have investigated strategies to quantify cardiac damage and stratify patients accordingly in different risk groups. The aim of this retrospective multicenter study was to provide a user-friendly simplified staging system based on the proposed classification system of Généreux et al. as a tool to evaluate the prognosis of patients undergoing TAVR more easily. Moreover, we analyzed changes in cardiac damage after TAVR. METHODS: We assessed cardiac damage in patients, who underwent TAVR at the Heart Center Bonn or Düsseldorf, using pre- and postprocedural transthoracic echocardiography. Patients were assigned to the staging system proposed by Généreux et al. according to the severity of their baseline cardiac damage. Based on the established system, we created a simplified staging system to facilitate improved applicability. Finally, we compared clinical outcomes between the groups and evaluated changes in cardiac damage after TAVR. RESULTS: A total of 933 TAVR patients were included in the study. We found a significant association between cardiac damage and 1-year all-cause mortality (stage 0: 0% vs. stage 1: 3% vs. stage 2: 6.6%; p < 0.009). In multivariate analysis, cardiac damage was an independent predictor of 1-year all-cause mortality (hazard ratio: 2.0, 95% confidence interval: 1.1-3.8; p = 0.03). CONCLUSIONS: In patients undergoing TAVR, cardiac damage is associated with enhanced mortality. A simplified staging system can help identify patients at high risk for an adverse outcome.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA